Página 1 - BSCDEMO User’s Guide

Simpact, Inc.9210 Sky Park CourtSan Diego, CA 92123 BSCDEMO User’s Guide DC 900-1349B September 1996

Página 2

10 DC 900-1349BBSCDEMO User’s Guide

Página 3 - Contents

DC 900-1349B 11Chapter1BSCDEMO CommandsBSCDEMO is an interactive demonstration program for use with all Simpact bisyn-chronous protocols. BSCDEMO is i

Página 4

12 DC 900-1349BBSCDEMO User’s GuideBSCDEMO can also be used to aid in debugging client applications. When registered asa Control session (available on

Página 5

1: BSCDEMO CommandsDC 900-1349B 13Table 1–1: BSCDEMO Commands and Options Command Option DescriptionATTACH Attach a client to a link. Mode field values

Página 6 - Hardware Support

14 DC 900-1349BBSCDEMO User’s Guide/P2 = n Clock source where valid values of n are:0 = external1 = internal2 = bypass/P3 = n Reply timer length where

Página 7

1: BSCDEMO CommandsDC 900-1349B 15/P10 = n Set data translation table where valid values of n are:0 = off1 = table 12 = table 2/P11 = n Station status

Página 8 - Protocol Support

16 DC 900-1349BBSCDEMO User’s Guide/P20 = n Block checking where valid values of n are:0 = off1 = exclude first character2 = include first character3 =

Página 9 - Customer Support

1: BSCDEMO CommandsDC 900-1349B 17/P30 = n DSR/DCD delay where valid values are n = 0–127 seconds. /P31 = n TTD/WACK limit where valid values are n =

Página 10 - 10 DC 900-1349B

18 DC 900-1349BBSCDEMO User’s GuideDISABLE STOPDisable a link. Turns off the DTR modem control signal and shuts down the link transmitter and receiver

Página 11 - BSCDEMO Commands

1: BSCDEMO CommandsDC 900-1349B 19KSIZE SIZE= n Display current size of input and output buffers where n is the new output buffer size in bytes. This

Página 12

Simpact, Inc.9210 Sky Park CourtSan Diego, CA 92123(619) 565-1865BSCDEMO User’s Guide© 1996 Simpact, Inc. All rights reservedPrinted in the United St

Página 13 - DC 900-1349B 13

20 DC 900-1349BBSCDEMO User’s GuideSEND Send EOT on link./ACK Send a positive safe store acknowledge command (ACK0 or ACK1, size = 0). Used to accept

Página 14 - 14 DC 900-1349B

1: BSCDEMO CommandsDC 900-1349B 21WRITE Write to the specified link. The /FILE option is the default./ESC Add simulated IBM 3780 print control sequenc

Página 15 - DC 900-1349B 15

22 DC 900-1349BBSCDEMO User’s Guide

Página 16 - 16 DC 900-1349B

DC 900-1349B 23AppendixABSC 3270 ExampleBSCDEMO is in the freeway/client/test/bscdemo directory. The following examplewas run immediately after the co

Página 17 - DC 900-1349B 17

24 DC 900-1349BBSCDEMO User’s GuideReceived ATTACH COMPLETE (46) from link 0Received ATTACH COMPLETE (46) from link 1bscdemo> b/c=1000 ! Ch

Página 18 - 18 DC 900-1349B

A: BSC 3270 ExampleDC 900-1349B 25 7 CHARACTER SET = 0(ASCII) 8 TRANSMIT BLOCK SIZE= 51210 DATA TRANSLATION = 1(TABLE 1) 11 STATION STATUS = 1(MASTER

Página 19 - DC 900-1349B 19

26 DC 900-1349BBSCDEMO User’s GuideWrite block size = 500Read block size = 2048bscdemo> e 0,1 ! Bind linksReceived START LINK (1) from link

Página 20 - 20 DC 900-1349B

A: BSC 3270 ExampleDC 900-1349B 27Received STATUS REPORT (13) from link 1Link is ON Mode is IDLEDTR is ON

Página 21 - DC 900-1349B 21

28 DC 900-1349BBSCDEMO User’s Guide 1>ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789 1>ABCDEFGHIJKLMNOPQRSTUVWXYZ01234

Página 22 - 22 DC 900-1349B

A: BSC 3270 ExampleDC 900-1349B 29Received STATISTICS RPT (15) from link 1BCC errors rcvd: 0Parity errors rcvd: 0RCV overrun errors: 0Buffer

Página 23 - BSC 3270 Example

DC 900-1349B 3 Contents Preface 51 BSCDEMO Commands 11A BSC 3270 Example 23B BSC 2780/3780 Example 33C FMP Example 41D SWIFT Example 49E CHIPS Exampl

Página 24

30 DC 900-1349BBSCDEMO User’s GuideReceived START LINK (1) from link 0Received START LINK (1) from link 1CONTROL> detach 0,1 ! Detach

Página 25 - DC 900-1349B 25

A: BSC 3270 ExampleDC 900-1349B 31Received STOP LINK (2) from link 0Received STOP LINK (2) from link 1bscdemo> detach 0,1 ! Detachi

Página 26

32 DC 900-1349BBSCDEMO User’s Guide

Página 27 - DC 900-1349B 27

DC 900-1349B 33AppendixBBSC 2780/3780 ExampleBSCDEMO is in the freeway/client/test/bscdemo directory. The following examplewas run immediately after t

Página 28 - 28 DC 900-1349B

34 DC 900-1349BBSCDEMO User’s GuideReceived ATTACH COMPLETE (46) from link 4Received ATTACH COMPLETE (46) from link 5bscdemo> c/p11 4 ! Configu

Página 29

B: BSC 2780/3780 ExampleDC 900-1349B 3517 SAFE STORE = 0(OFF) 19 MESSAGE BLOCKING = 1(DATA)20 BLOCK CHECKING = 1(EXCLUDE) 21 READ QUEUE LIMIT = 022 EO

Página 30

36 DC 900-1349BBSCDEMO User’s GuideData state: 0 Last DATA event: NullLast BSCISR event: 0Received STATUS REPORT (13) from lin

Página 31 - DC 900-1349B 31

B: BSC 2780/3780 ExampleDC 900-1349B 37 5>ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789 5>ABCDEFGHIJKLMNOPQRSTUVWXYZ0

Página 32 - 32 DC 900-1349B

38 DC 900-1349BBSCDEMO User’s GuideReceived STOP LINK (2) from link 4Received STOP LINK (2) from link 5CONTROL> e 4,5Received START

Página 33 - BSC 2780/3780 Example

B: BSC 2780/3780 ExampleDC 900-1349B 39Received ERROR REPORT (0) from link 5with ERROR 11 -- Data Set Ready (DSR) down**** Data Set Ready (DSR) d

Página 34

4 DC 900-1349B BSCDEMO User’s Guide

Página 35 - DC 900-1349B 35

40 DC 900-1349BBSCDEMO User’s Guide

Página 36 - 36 DC 900-1349B

DC 900-1349B 41AppendixCFMP ExampleBSCDEMO is in the freeway/client/test/bscdemo directory. The following examplewas run immediately after the communi

Página 37

42 DC 900-1349BBSCDEMO User’s GuideReceived ATTACH COMPLETE (46) from link 0bscdemo> b/c=512 ! Configure client Message Buffer Size (optional) !

Página 38

C: FMP ExampleDC 900-1349B 43bscdemo> l 2,3 ! Get a Link Configuration ReportReceived CONFIG REPORT (14) from link 2 1 DATA RATE = 9(9600) 2 CLOC

Página 39 - DC 900-1349B 39

44 DC 900-1349BBSCDEMO User’s GuideWrite block size = 1024 Read block size = 2048bscdemo> k=200 ! Change output buffer sizeWrite block size = 200 R

Página 40 - 40 DC 900-1349B

C: FMP ExampleDC 900-1349B 45Received DATA ACK (7) from link 2 Unit: 0 Device: 0bscdemo> r 3 ! To display data: Use r/i command, or ! use read com

Página 41 - FMP Example

46 DC 900-1349BBSCDEMO User’s GuideINPUT BUFFER (HEX 16): HEADER: 0 17 0 0 0 2 0 0 0 0 0 0 0 0 0 16 v-START OF DATA 0 14 0 0 0 20 21 22 23 24 25 26 27

Página 42

C: FMP ExampleDC 900-1349B 47Error reading data -1 error# -10503Error reading data -1 error# -10503CONTROL> i/cCONTROL NODE DISABLEDbscdemo> d 2

Página 43 - DC 900-1349B 43

48 DC 900-1349BBSCDEMO User’s Guide

Página 44

DC 900-1349B 49AppendixDSWIFT ExampleBSCDEMO is in the freeway/client/test/bscdemo directory. The following examplewas run immediately after the commu

Página 45

DC 900-1349B 5 Preface Purpose of Document This document describes how to use the BSCDEMO interactive demonstration pro-gram for Simpact’s bisynchron

Página 46

50 DC 900-1349BBSCDEMO User’s GuideReceived ATTACH COMPLETE (46) from link 4Received ATTACH COMPLETE (46) from link 5bscdemo> c/p11 4 ! Configu

Página 47

D: SWIFT ExampleDC 900-1349B 5114 RETRY LIMIT = 2 16 MODEM CONTROL = 1(FDX)17 SAFE STORE = 0(OFF) 19 MESSAG

Página 48 - 48 DC 900-1349B

52 DC 900-1349BBSCDEMO User’s GuideReserved : 0 Reserved : NullDSR is ONReceived STATUS REPORT (13) from link 5Link is ON

Página 49 - SWIFT Example

D: SWIFT ExampleDC 900-1349B 53 5>ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789ABCDEFGHIJKLMNOPQR 5>ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789ABCDEFGHIJKLMNOPQ

Página 50

54 DC 900-1349BBSCDEMO User’s GuideReceived ATTACH COMPLETE (46) from link 4Received ATTACH COMPLETE (46) from link 5CONTROL> d 4,5Received STO

Página 51 - DC 900-1349B 51

D: SWIFT ExampleDC 900-1349B 55bscdemo> d 4,5 ! Unbind linksReceived STOP LINK (2) from link 4Received STOP LINK (2) from link 5bsc

Página 52 - 52 DC 900-1349B

56 DC 900-1349BBSCDEMO User’s Guide

Página 53

DC 900-1349B 57AppendixECHIPS ExampleBSCDEMO is in the freeway/client/test/bscdemo directory. The following examplewas run immediately after the commu

Página 54

58 DC 900-1349BBSCDEMO User’s GuideReceived ATTACH COMPLETE (46) from link 4Received ATTACH COMPLETE (46) from link 5bscdemo> c/p11 4 ! Configu

Página 55 - DC 900-1349B 55

E: CHIPS ExampleDC 900-1349B 5914 RETRY LIMIT = 6 16 MODEM CONTROL = 1(FDX)17 SAFE STORE = 0(OFF) 19 MESSAG

Página 56 - 56 DC 900-1349B

6 DC 900-1349B BSCDEMO User’s Guide Organization of Document Chapter 1 is an overview of the BSCDEMO interactive commands.Appendix A is an example BS

Página 57 - CHIPS Example

60 DC 900-1349BBSCDEMO User’s GuideReceived STATUS REPORT (13) from link 5Link is ON Mode is IDLEDTR is ON

Página 58

E: CHIPS ExampleDC 900-1349B 61Received NORMAL DATA-ETX (17) from link 5Unit: 0 Device: 0 Size: 500 5>ABCDEFGHIJKLMNOPQRSTUVWXYZ01234

Página 59 - DC 900-1349B 59

62 DC 900-1349BBSCDEMO User’s GuideReceived ATTACH COMPLETE (46) from link 4Received ATTACH COMPLETE (46) from link 5CONTROL> d 4,5Received STO

Página 60 - 60 DC 900-1349B

E: CHIPS ExampleDC 900-1349B 63bscdemo> d 4,5 ! Unbind linksReceived STOP LINK (2) from link 4Received STOP LINK (2) from link 5bsc

Página 61

64 DC 900-1349BBSCDEMO User’s Guide

Página 62

BSCDEMO User’s GuideDC 900-1349BCustomer Report FormWe are constantly improving our products. If you have suggestions or problems you wouldlike to rep

Página 63 - DC 900-1349B 63

Simpact, Inc.Customer Service9210 Sky Park CourtSan Diego, CA 92123

Página 64 - 64 DC 900-1349B

Preface DC 900-1349B 7 • ICP2424 Hardware Description and Theory of Operation DC 900-1328 • ICP2432 Hardware Description and Theory of Operation DC 9

Página 65 - Customer Report Form

8 DC 900-1349B BSCDEMO User’s Guide Document Conventions The term “Freeway” refers to any of the Freeway server models (for example, Freeway1100/1150

Página 66 - San Diego, CA 92123

Preface DC 900-1349B 9 Revision History The revision history of the BSCDEMO User’s Guide , Simpact document DC 900-1349,is recorded below: Customer